Testing

Ensign Power Systems Inc …. High Reliability Custom Power Supplies

 

Testing Capabilities (In-house & Local)
Tests Performed Specifications Comments
HALT / HASS ( In-house ) As Defined +/- 40 Degree C/Min
Temperature Tests ( In-house ) MIL-STD-810 -55 to +125°C
Humidity ( In-house ) MIL-STD-810
Altitude MIL-STD-810 to 70,000 ft.
Shock and Vibration MIL-STD-810
Salt Fog MIL-STD-810
Explosive Atmosphere MIL-STD-810
Electromagnetic Compatability MIL-STD-461 and 462

 

Other Environmental and Performance Qualification and Testing as Requested by Customers

Qualification:

Ensign Power Systems is fully capable of qualifying all products we design for both product performance characteristics and use in environmental conditions.  We provide all documentation required.  We also can provide in-house development and testing for HALT-HASS.  We qualify to all required military standards.